Check for Errors
Review only on control computer to identify any error messages on the screen. Error 30369
If Pandoras Box software is not open or it is not have access, access it through RealVNC:
Open the RealVNC software.
Select the screen with the IP address or write your own PB IP Address: XXX.XXX.XXX.XXX
Click to connect.
When prompted for a DEFAULT password, enter: Pandoras.
Once connected, check the Pandoras Box window for the error message.
Take a screenshot to save the Error.
If the same error has occurred repeatedly and Pandoras Box crashes, write down the exact date and time of the incident.
This information is required for tracking and updating the active support ticket.
Image 1. AVRK3-GPC1 screen
Restart Pandoras Box
After recording the error details, close or end the current task and open the Pandoras Box software again.
When prompted to open or create a new project, select “Open”.
In the folder that appears "This PC/Local Disk (C:)/Christie/content/projects/, locate and open the correct project file
Project File Name: Fear_Not_Show_Test.pbb
This will load the proper backup of the Pandoras Box project.
Image 2. Pandoras Box Open Files.
Access the Sequence Inspector
Go to the top left corner of the screen and click “Project.”
From the drop-down menu, select “Sequences.”
A small submenu will appear; click on the file named [1] unnamed (indicated by a clock icon).
Once selected, the Inspector window (on the right side of the screen) will update, confirming that you are viewing the inspector for that specific sequence.
Reset and check the design again
Image 3. Pandora's Box Principal Screen.